Colomer-Farrarons, Jordi; Miribel-Catala, Pere Luis

A CMOS Self-Powered Front-End Architecture for Subcutaneous Event-Detector Devices Three-Electrodes Amperometric Biosensor Approach (Gebundene Ausgabe)

Springer-Verlag GmbH, Springer Netherland, Februar 2011


Edition - 200 S. - Sprache: Englisch - 120 schwarz-weiße und 25 farbige Abbildungen, 34 schwarz-weiße Tabellen - 243x163x20 mm Book

ISBN: 9400706855 EAN: 9789400706859

A CMOS Self-Powered Front-End Architecture for Subcutaneous Event-Detector Devices presents the conception and prototype realization of a Self-Powered architecture for subcutaneous detector devices. The architecture is designed to work as a true/false (event detector) or threshold level alarm of some substances, ions, etc... that are detected through a three-electrodes amperometric BioSensor approach. The device is envisaged as a Low-Power subcutaneous implantable application powered by an inductive link, one emitter antenna at the external side of the skin and the receiver antenna under the skin. The sensor is controlled with a Potentiostat circuit and then, a post-processing unit detects the desired levels and activates the transmission via a backscattering method by the inductive link. All the instrumentation, except the power module, is implemented in the so called BioChip. Following the idea of the powering link to harvest energy of the magnetic induced link at the implanted device, a Multi-Harvesting Power Chip (MHPC) has been also designed.


Preis: 139,09 EUR
Versandkosten: 0,00 EUR
Gesamtpreis: 139,09 EUR
In den Warenkorb

Anbieter: MARZIES.de Buch- und Medienhan… (Impressum/Lieferzeit)
Katalog: HC/Elektronik/Elektrotechnik/Nachrichtentechnik

Angebotene Zahlungsarten: Vorauskasse
Transparente Bestellabwicklung - Verkäufer nutzt Order-Control - klicken für mehr Information
Transparente Bestellabwicklung -
Verkäufer nutzt Order-Control

 

Produktdetails

Full conception for a subcutaneous device as an event-detector, which is the basis for more sophisticated systems like controlled-release drug delivery systemsFocus the interest to implanted systems submitting only critical values to external control unitWhole electronically complexity architecture is presented: energy scavening, measurement-communication

Inhaltsverzeichnis

Preface / Abstract. Abbreviations. 1 Introduction. 1.1 Energy Harvesting in Human and Non-Human Activities. 1.2 BioSensors. 1.3 Circuits for Three Electrodes BioSensors. 1.4 Contribution of this Book. 1.5 Outline of the Book. 1.6 References.2 Energy Harvesting (Multi Harvesting Power Chip). 2.1 Multi Harvesting Power Chip (MHPC). 2.2 Solar and Inductive Power Harvesting. 2.3 Piezoelectric Harvesting. 2.4 Chapter Conclusions. 2.5 References.3 Biomedical Integrated Instrumentation. 3.1 General Introduction to Biomedical Instrumentation. 3.2 Electrochemical Biosensors. 3.3 Potentiostat (Sensor Instrumentation). 3.4. Low-Frequency Lock-In Amplifier. 3.5 Biotelemetry for Implanted Devices. 3.6 Chapter Conclusions. 3.7 References.4 CMOS Front-End Architecture for In-Vivo Biomedical Subcutaneous Detection Devices. 4.1 Introduction. 4.2 Front-End General Architecture. 4.3 Prototypes  Design and Results. 4.4 Chapter Conclusions. 4.5 References. 5 Conclusions and Future Work. 5.1 Conclusions. 5.2 Future Work.Appendix 1. Appendix 2. Appendix 3.

Über den Autor

Dr. Jordi Colomer-Farrarons received his BSc. degree in Electrical Engineering from EUSS (Salesians Technical Engineering School) in 2002. From 2002 to 2005 he worked as hardware design engineer at the automotive company Francisco Albero SA. In 2005, he received his MSc. degree in Electrical Engineering from University of Barcelona (UB). In 2010 he received his PhD degree from the UB. Since 2009, he works as fellow researcher at the BioEngineering and NanoBioEngineering-SIC-BIO Group of the UB, focusing on low-voltage low-power circuits, smart power, harvesting circuits, interface circuits for biomedical applications, and microelectronic design. From April to July 2009, he joined the Designs Service Department at IMEC's INVOMEC Divison (Belgium). Dr. Pere Miribel-Català received his MSc. degree in Physics from the University of Barcelona (UB) in 1994. From 1993 to 1999 he was research fellow at Systems for Instrumentation and Communications Laboratory (SIC Lab) of the University of Barcelona working on high voltage smart power circuits and microelectronic design. He was visiting research fellow in 1998 at LAAS-CNRS laboratory (Toulouse, France). He received his PhD degree from the University of Barcelona in 2000. He also worked designing power management integrated DCDC converters during a postdoctoral stage at the design center of ON semiconductor Inc. (Toulouse, France). Since 2003 he is Associate Professor at the Electronics Department and part of the BioEngineering and NanoBioEngineering-SICBIO Group of the University of Barcelona. His research topics are focused on low-voltage low-power integrated circuits, interface and analog processing circuits, particularly for biomedical applications, smart power and power management circuits.


ISBN 9-400706-85-5, ISBN 9-40-070685-5, ISBN 9-40070-685-5, ISBN 9-400-70685-5, ISBN 9-4007-0685-5

ISBN 978-9-400706-85-9, ISBN 978-9-40-070685-9, ISBN 978-9-40070-685-9, ISBN 978-9-400-70685-9, ISBN 978-9-4007-0685-9

Buch empfehlen Buch empfehlen
Sparen Sie Versandkosten beim Kauf weiterer Artikel dieses Buchhändlers.

Mechatronics for Cultural Heritage and Civil Engineering von Ottaviano, Erika (Herausgeber); Pelliccio, Assunta (Herausgeber); Gattulli, Vincenzo (Herausgeber)
160,49 EUR
Meine zuletzt angesehenen antiquarischen und neue Bücher
Meine letzten Buch Suchanfragen
    Noch keine Suchanfragen vorhanden.

© 2003 - 2018 by whSoft GmbH
Entdecken Sie außerdem: Antiquariatsportal · Achtung-Bücher.de · Booklink · Buchhai - Bücher Preisvergleich
Alle genannten Preise sind Bruttopreise und enthalten, soweit nicht anders vom Verkäufer angegeben, die gesetzliche Umsatzsteuer.